PC9155 Wireless Alarm Panel
6-3
[][2] Troubles
Power up system
Enter [][2] to view Troubles
•Perform actions indicated in the tables below
[][2] Trouble Summary
Trouble [0] GPRS/Ethernet Module Trouble
Trouble [1] Service Required - Press [1] for more information
Low Battery
General System Trouble
General System Tamper
Trouble [2] AC Trouble
Trouble [3] Telephone Line Trouble
Trouble [4] Failure to Communicate
Trouble [5] Device Fault - Press [5] for more information
Trouble [6] Device Tamper - Press [6] for more information
Trouble [7] Wireless Device Low Battery - Press [7] for more information
Trouble [8] Loss of Time or Date
Trouble Cause Troubleshooting
Trouble [0] GPRS/Ethernet Module Trouble Press [<][>] to determine specific trouble
Alternate Comm SIM Lock
The SIM lock feature has been enabled
and the unit has not been programmed
with the correct PIN for the SIM card.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
GPRS/Ethernet Module
Trouble
This condition is created when the
GPRS/Ethernet module has detected a
radio or SIM failure, a GPRS network
trouble, or insufficient signal strength.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
Alternate Comm GSM
Trouble
This condition is created when the
GPRS/Ethernet module has detected a
network absent condition.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
Alternate Comm Receiver
Trouble
This condition is generated when the
GPRS/Ethernet module loses
supervision or fails to initialize a receiver.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
Alternate Comm Fault
This condition is created when the
PC9155 loses communication with an
Ethernet or GPRS module on the
system.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
Alternate Comm Config
SMS Trouble
This condition is created when the
GPRS/Ethernet module detects a
Connect 24 Configuration SMS failure
trouble.
Please refer to the TL260GS/TL265GS/GS2060/GS2065
Installation Manual for more details.
Trouble [1] Service Required Press [1] to determine specific trouble
Low Battery
Main panel battery less than 11.4V
+/- 0.1V.
NOTE: This trouble condition will not
clear until the battery voltage is 12.5V
+/- 0.1V.
NOTE: If battery is new allow 24 hrs. for battery to charge.
Verify voltage measured across AC terminals is 16-18 VAC.
Verify voltage measured across battery terminals is 12.5V +/- 0.1V.
Replace transformer if required.
Disconnect then reconnect battery leads.
General System Trouble
The system has detected the presence
of a RF Jam for 20 seconds or
communications with the wireless
receiver have failed causing a hardware
fault.
Check Event Buffer to determine specific trouble.
If buffer logs RF Jam trouble: check for external 433MHZ signal sources.
To disable RF Jam, enable option [7] in program section [804]
subsection [900].
If buffer logs ‘Hardware Fault’ - replace panel.
General System Tamper
Cover tamper tripped. Verify that tamper buttons are installed into backplate and front-
plate, and that the frontplate is fully in place.
Verify that the panel is properly secured to the wall with the front
cover on.