5.3 Programming Descriptions
5-45
[804][330] WT4911 Maximum Bell Activation Time
This value determines the maximum time the wireless bell/siren will sound before automatically turning off.
[804][900] General Wireless Options
[851] GPRS/Ethernet Module Programming
Refer to the associated manual for programming details.
[898] Wireless Device Enrolment
See Chapter 2 for details.
[899] Template Programming
See Chapter 4 for details.
[900] Alarm System Version
When this section is entered the version of the panel is displayed as a 4-digit decimal entry.
E.g., The entry 1234 = Version 12.34. This is a read-only value.
[904] Wireless Module Placement Test
See Chapter 2 for details.
[905] Wireless Keypad Placement Test
See Chapter 2 for details.
[906] Wireless Siren Placement Test
See Chapter 2 for details.
[990] Installer Lockout Enable
This feature is designed to prevent installers other than the original from resetting the panel. If enabled, the panel gives a distinctive audible indication on power up
(the phone line relay will click 10 times). If a hardware default is attempted while lockout is enabled, the default does not occur and the false default attempt is
logged to the event buffer. This feature has no effect on a software default (all programming returns to the factory defaults).
[991] Installer Lockout Disable
This section disables the Installer Lockout feature described above.
[996] Restore Wireless Default Programming
All programming in section [804] Wireless Device Programming returns to the factory defaults.
[998] Restore Panel Default Programming
All programming in the PC9155 returns to the factory defaults, except for the Wireless Device Programming sections.
[2]
ON: Pre-Alarm Signal Enabled. When the system begins entry delay the entry delay time is sent to the wireless siren. If the wireless siren does not
receive a disarm command during the entry delay time, the siren will go into alarm.
OFF: Pre-Alarm Signal Disabled. When the system begins entry delay no entry delay time is sent to the wireless siren. The siren will not go into
alarm until it receives a signal from the panel to tell it to go into alarm.
[3]
ON: Strobe Squawks Enabled. This feature provides a visual indication on outdoor sirens when the system has been successfully armed or disarmed
without sounding the siren.
One flash indicates that the system has been armed.
Two flashes indicate the system has been disarmed with no alarms in memory.
Three flash pairs indicates the system has been disarmed with alarms in memory.
OFF: Strobe Squawks Disabled. Outdoor siren LEDs will not flash (strobe) during arming or disarming.
i
This option functions independently of the programming in section [014] Opt. 1.
[4]-[8]
For Future Use
When these options are enabled or disabled, they affect all wireless devices on the system.
Option Description
[1]
For Future Use
[2]-[6]
For Future Use
[7]
ON: RF Jam Disabled. RF Jam conditions will NOT be detected, displayed and communicated.
OFF: RF Jam Enabled. RF Jam conditions will be detected, displayed and communicated.
[8]
ON: Global Placement Test. Module selection is NOT required for the placement test. Entering section [904]-[906] begins the testing. All zones,
keypads, and sirens that are enrolled are tested. Individual devices do not have to be selected.
OFF: Individual Module Placement Test. On entering section [904]-[906] a 2-digit entry is required to select the zone, keypad or siren to be tested.